Available 24 Hours for Emergencies 215-500-2754

RENTALS


Though Advanced Mechanical is primarily a service provider, we also offer rental equipment to our customers. Any client that needs a temporary or emergency cooling or heating solution can come to us for their rental needs. We serve hospitals, pharmacies, nursing homes, stores, restaurants, outdoor venues, and more. The rental equipment is delivered on site whenever you need it and we install it. The equipment is typically on wheels so if a customer should need to move it for whatever reason, that can be done easily. When you’re done using the equipment, just give us a call and we’ll be right there to retrieve it.

1
Yes
None
1
1000000
Name...
/rentals/
Thumbnail
Clear All

Categories:

Sub-Categories:

Tags:

Office Pro 12
Office Pro 12 Image

Cooling Capacity (95° at 60% RH) (Btu/Hr)
1 Ton 12,000
Air Flow (CFM, High/Low) Evaporator
410/380
Air Flow (CFM, High/Low) Condenser
820/715
Operating Conditions (Min-Max) (at 50% RH)
65°-95°F
Voltage
115/1

Office Pro 18
Office Pro 18 Image

Cooling Capacity (95° at 60% RH) (Btu/Hr)
1.5 Ton 16,800
Air Flow (CFM, High/Low) Evaporator
540/500
Air Flow (CFM, High/Low) Condenser
770/710
Operating Conditions (Min-Max) (at 50% RH)
65°-95°F
Voltage
115/1

Office Pro 24
Office Pro 24 Image

Cooling Capacity (95° at 60% RH) (Btu/Hr)
2 Ton 24,000
Air Flow (CFM, High/Low) Evaporator
630/545
Air Flow (CFM, High/Low) Condenser
870/760
Operating Conditions (Min-Max) (at 50% RH)
65°-95°F
Voltage
208-230/1

Office Pro 36
Office Pro 36 Image

Cooling Capacity (95° at 60% RH) (Btu/Hr)
3 Ton 36,000
Air Flow (CFM, High/Low) Evaporator
990/825
Air Flow (CFM, High/Low) Condenser
1490/1060
Operating Conditions (Min-Max) (at 50% RH)
65°-95°F
Voltage
208-230/1

Office Pro 60
Office Pro 60 Image

Cooling Capacity (95° at 60% RH) (Btu/Hr)
5 Ton 60,000
Air Flow (CFM, High/Low) Evaporator
1940/1770
Air Flow (CFM, High/Low) Condenser
2830/2650
Operating Conditions (Min-Max) (at 50% RH)
65°-105°F
Voltage
208-230/1

Office Pro 63
Office Pro 63 Image

Cooling Capacity (95° at 60% RH) (Btu/Hr)
5 Ton 60,000
Air Flow (CFM, High/Low) Evaporator
1940/1770
Air Flow (CFM, High/Low) Condenser
2830/2650
Operating Conditions (Min-Max) (at 50% RH)
65°-105°F
Voltage
460/3

Office Pro 12 Image
Office Pro 12
Cooling Capacity (95° at 60% RH) (Btu/Hr) 1 Ton 12,000 Air Flow (CFM, High/Low) Evaporator 410/380 Air Flow (CFM, High/Low) Condenser 820/715 Operating Conditions (Min-Max) (at 50% RH) 65°-95°F Voltage 115/1
Office Pro 18 Image
Office Pro 18
Cooling Capacity (95° at 60% RH) (Btu/Hr) 1.5 Ton 16,800 Air Flow (CFM, High/Low) Evaporator 540/500 Air Flow (CFM, High/Low) Condenser 770/710 Operating Conditions (Min-Max) (at 50% RH) 65°-95°F Voltage 115/1
Office Pro 24 Image
Office Pro 24
Cooling Capacity (95° at 60% RH) (Btu/Hr) 2 Ton 24,000 Air Flow (CFM, High/Low) Evaporator 630/545 Air Flow (CFM, High/Low) Condenser 870/760 Operating Conditions (Min-Max) (at 50% RH) 65°-95°F Voltage 208-230/1
Office Pro 36 Image
Office Pro 36
Cooling Capacity (95° at 60% RH) (Btu/Hr) 3 Ton 36,000 Air Flow (CFM, High/Low) Evaporator 990/825 Air Flow (CFM, High/Low) Condenser 1490/1060 Operating Conditions (Min-Max) (at 50% RH) 65°-95°F Voltage 208-230/1
Office Pro 60 Image
Office Pro 60
Cooling Capacity (95° at 60% RH) (Btu/Hr) 5 Ton 60,000 Air Flow (CFM, High/Low) Evaporator 1940/1770 Air Flow (CFM, High/Low) Condenser 2830/2650 Operating Conditions (Min-Max) (at 50% RH) 65°-105°F Voltage 208-230/1
Office Pro 63 Image
Office Pro 63
Cooling Capacity (95° at 60% RH) (Btu/Hr) 5 Ton 60,000 Air Flow (CFM, High/Low) Evaporator 1940/1770 Air Flow (CFM, High/Low) Condenser 2830/2650 Operating Conditions (Min-Max) (at 50% RH) 65°-105°F Voltage 460/3